ESD
Packaging
All E-STAB-REL Carriers produced by LIFE LINE PACKAGING, INC.
are treated with “staticide” topical antistat solution
that complies with the electrostatic criteria outlined in MIL-PRF-81705D
and National Fire Protection Code 56A, as tested in accordance
with Federal Test Standard 101C Method 4046, following guidelines
established by the Official Military Handbook #263 outlining criteria
for Electrostatic Discharge Control for electric and electronic
devices, components, assemblies, and equipment called out in MIL-STD-1686C.
Sample specimens from
all production runs of E-STAB-REL Carriers are tested by our in-plant
laboratory, using a static decay measurement rate of 5000 volts
to 0 volts. These measurements are made with an Electro Tech Systems
Static Decay Meter, with Faraday Cage and Humidity Test Chamber.
Testing is conducted at 15% relative humidity.
All staticide coated
E-STAB-REL Carriers tested to date have shown an average static
decay rate of .57 seconds or less for both positive and negative
polarity charges.
E-STAB-REL Carriers
contain no N-Octanoic acid.
Note
The above Federal Test Standard 101C Method 4046 allows all packages
with a decay rate of 2.0 seconds or less to be classified as SAFE
ANTI-STATIC PACKAGING ACCEPTABLE TO ALL MILITARY STANDARDS.